XSL series inspection instrument

You can set the total number of channels used. You can also arbitrarily close the channels that you do not care about temporarily so that they do not participate in the tour display and alarm comparison.
INQUIRY
Description

◆8-80 input channels, aluminum alloy housing, plug-in terminal blocks
◆0.2-level accuracy, measurement and control speed of 0.1 seconds or 0.2 seconds per channel (thermocouple channel)
◆ Can input thermal resistance, thermocouple, DC current, DC voltage signal
◆ 2-digit channel number display, 4-digit measurement value display, display range -199-9999
◆ The thermal resistance display resolution is 0.1 ℃. The thermocouple display resolution can be set to 1 or 0.1 ℃ through parameters. (Each channel is set independently)
◆ Can set the total number of channels used. You can also arbitrarily close the channels that you do not care about temporarily so that they do not participate in the tour display and alarm comparison.
◆ Each channel independently sets the signal type and range.
◆ The digital filter time constant is independently set for each channel to improve the display stability.
◆ Zero and full-scale correction can be set independently for each channel to improve system measurement accuracy.
◆ With fixed-point display function, easy to adjust.
◆ With parameter copy function to quickly set parameters, greatly reducing the workload of parameter setting
◆ Standard communication interface, can choose RS232 or RS485TCASC protocol or modbus--rtu protocol
◆ Optional print function. Can realize manual, timing, alarm printing.
◆ Alarm function:
①Each channel has 4 independent alarm settings and independent upper or lower alarm modes
② Independent alarm indicator for each channel
③ 4-point alarm output, 2 configurable alarm output modes.
Method 1: The working mode of the flash alarm.
The first point of alarm output is closed when any channel enters the alarm state from non-alarm state: automatic delay recovery (confirmation) or panel key recovery (confirmation).
2nd point alarm output: As long as 1 channel is in alarm state, it will be closed.
The alarm indicator of each channel has three states:
① Not lit, it means the channel is in non-alarm state.
② Blinking: It indicates that the channel enters the alarm state from the non-alarm state, and there is no automatic delay confirmation or panel key confirmation.
③ On: The channel is in alarm state and has been confirmed.
Mode 2 The two alarm setpoints of each channel are shared.
1st point alarm output: The 1st alarm setpoint of any 1 channel is closed in the alarm state.
2nd point alarm output, the 2nd alarm set point of any 1 channel is closed in the alarm state.
The third point alarm output, the third alarm set point of any 1 channel is closed in the alarm state.
The 4th alarm output, the 4th alarm setpoint of any 1 channel is closed in the alarm state.

Model code Technical specifications
XSL- 8 ~ 80 channel input 0.2 level display accuracy: measurement and control speed (up to 0.1 second × number of channels)
Dimensions A 160×84×142mmHorizontal opening size: 152 × 76
B 84×160×142mmVertical hole size: 76 × 152
C 160×160×182mm      Cut-out size: 152 × 152
D1 318×104×300mmDesktop
D2 318×104×300mmPanel mounting hole size: 312 × 96
Panel specifications 2-digit LED (channel number display) + 4-digit LED (measured value display)
Number of channels 8~80 A, B size meters can choose up to 32 channels C, D1, D2 size meters can choose up to 80 channels
Input signal (other signal input, please specify when ordering) R All channels are thermal resistance, Pt100 Cu10 0Cu50 BA1, BA2 G53
E All channels are thermocouples, K, SR, B, NE, J, T
B All channels are DC current ((4-20) mA / (0-10) mA / (0-20) mA) B or DC voltage ((0-5) V / (1-5) V) signals.
Need to specify the input channels of current and voltage signals when ordering
X All channels are thermal resistance (P100 / Cu0 / Cu50 / BA1 / BA2 / G53) thermocouple (K / S / R / B / N / E / J / T) mixed use
L All channels are thermal resistance (Pt100 / Cu100 / C50 / BA1 / BA2 / G53) thermocouples (K / S / R / B / N / E / J / T), DC current ((4-20) ma / ( 0-10) ma / (0-20) mA) DC voltage ((0-5) V / (1-5) V) mixed. Need to specify the input channel of the current voltage signal when ordering
alarm 4 points public alarm relay output, 250V AC / 3A, resistive load
Communication (option)
(Communication rate: 2400 4800 9600 19200)
(Communication address 0-99)
S1 TCASCprotocolR232
S2 TCASCprotocolR485
M1 modbus--RTUprotocolRS232
M2 modbus--TRUprotocolRS485
Print interface (optional)
M1M2 communication method can no longer be  for printing
P1 Print interface
P2 All-in-one printing (limited to D1 D2 size, alarm indicator in 32 channels)
Power Specifications V0 100-240V AC 50/60Hz
V1 10-24V AV 50/60 Hz;10-24V DC