Contact Us
5th Floor, Jingwei Building, 7 Yanzheng Middle Avenue, Wujin District, Changzhou City, Jiangsu Province, China
+86-519 86577655
flowmetercn.com
You are here: Home > process analytics

XSC5 Series PID Regulator

Point alarm output, select 12 alarm modes. Alarm sensitivity can be set independently With delayed alarm function, effectively prevent false alarms caused by interference and other reasons
INQUIRY
Description

◆ 0.2-level accuracy, measurement and control cycle is 0.2 seconds.
◆ Advanced PD intelligent control algorithm, anti-overshoot and self-tuning (AT) function.
◆ 3 points alarm output, select 12 alarm modes. Alarm sensitivity can be set independently. With delayed alarm function, effectively prevent false alarms caused by interference and other reasons
Model code Technical specifications
XSC5- 0.2-level measurement accuracy; 5 control speeds per second, self-tuning
Dimensions AH 160 × 80 × 125mm horizontal opening size, 152 × 76
AS 80 × 160 × 125mm vertical hole size: 76 × 152
B 96 × 96 × 112mm opening size, 92 × 92
CH 96 × 48 × 112mm horizontal opening size: 92 × 45
CS 48 × 96 × 112m vertical opening size: 45 × 92
D 72 × 72 × 112m hole size: 68 × 68
E 48x48x112mm hole size: 45.5 × 45.5
Panel specifications 4-digit LED + 4-digit LED set value display
input signal
Other input signals
Instructions when ordering
E Thermocouple K S R B N E J T
R Thermal resistance Pt100, Cu100, Cu50, BA1, BA2, G53
I DC current (4-20) mA. (0-10) mA. (0-20) mA
V DC voltage (0-5). (1-5) V
M mV signal (order range specified)
W potentiometer
L remote pressure gauge
Alarm (option) 250V AC / 3A, resistive load T1~3 1 ~ 3 points alarm relay output; CH CS D E only has 1 point electrical output
Control output
(CH CS D E size instrument
C5 C6 output mode is not supported)
C1 Current output (4 ~ 20) mA (0 ~ 10) mA (0 ~ 20) mA
C2 Voltage output (1 ~ 5) V (0 ~ 5) V
C3 Voltage output (0 ~ 10) V
C4 Solid state relay drive voltage output
C5 Thyristor non-contact normally open output
C6 SCR zero-cross trigger output
C7 Relay contact switch output
Transmit (optional)
(Resolution: 1/3000; load capacity: 600Ω)
(CH CS D E size instrument control output mode is
C1 C2 C3, does not support transmission output)
A1 Current output (4 ~ 20) mA (0 ~ 10) mA (0 ~ 20) mA
A2 Voltage output (1 ~ 5) V (0 ~ 5) V
A3 Voltage output (0 ~ 10) V
External power supply (option) B1 24±5% 50mA以下
B1G 24±5% 50mA以下
B2 12±5% 50mA以下
B2G 12±5% 100mA以下
B3 Precision power supply, generally 10V ± 2%, 300ppm below 100mA
Communication (option)
Communication speed: 2400, 4800, 9600, 19200
Communication address: 0 ~ 99
S1 TC ASC II protocol RS232
S2 TC ASC II protocol RS485
M1 Modbus-RTU protocol RS232
M2 Modbus-RTU protocol RS485
Power Specifications V0 100-240V VC 50/60Hz
V1 10-24V AC 50/60Hz;10-24V DC

Maybe you like