LWGY type turbine flow sensor (hereinafter referred to as sensors) is a precision flow measurement instruments, with the corresponding Flow totalizer can be used to measure liquid supporting the flow and volume.
INQUIRY
Description SELECTION CRITERIA INSTALLATION AND USE FIELD INSTALLATION

The brochure describes LWGY turbine flow meter standard technical specifications, model and its installation, operation and maintenance. But in the manual it does not describe the different characteristics of users, and also no revised amendments at the end of each technical point of order, structure or components, because some equipment modifications will not affect the function and operation.
LWGY type turbine flow sensor (hereinafter referred to as sensors) is a precision flow measurement instruments, with the corresponding Flow totalizer can be used to measure liquid supporting the flow and volume. It is widely used as measurement, control system in petroleum, chemical, metallurgy, scientific research areas.
Sensors and output amplifiers have a wide range of combinations (see Model specifications code form), the sensor can be used with the control room of the second instrument or controller connected to the plot to achieve balance, transmission and control functions.

1) .High accuracy. Generally up to 1% R, 0.5% R
2) .Good repeatability, short-term repeatability can reach 0.05% ~ 0.2%. It is precisely because of good repeatability, such as regular calibration or online calibration can get very high accuracy, which is the preferred flow in trade settlement meter
Output pulse frequency signal, suitable for total measurement and no zero drift when connected with computer, strong anti-interference ability:
3) .High frequency signal (3 ~ 4kHz) can be obtained with strong signal resolution
4). Wide range, medium and large caliber can reach 1:20. Small caliber can be 1:10
5) .Compact and lightweight structure, easy installation and maintenance, large circulation capacity
6) .Suitable for high pressure measurement, there is no need to make holes in the body of the meter, and it is easy to make high voltage instruments
7) .There are many types of special-purpose sensors, which can be designed as various types of special-purpose sensors according to the special needs of users, such as low-temperature type, two-way type, downhole type, and sand-mixing type.
8). Can be made into a plug-in type, suitable for large-caliber measurement, low pressure loss, low price, can be continuously removed, convenient installation and maintenance.
  1.fastener
  2.case
  3.Front guide
  4.Thrust piece
  5.impeller
  6.Magnetic-electric induction signal detector
  7.Bearing
  8.Rear guide

 
Instrument caliber and connection 4, 6, 10, 15, 20, 25, 32, 40 are threaded
(4, 6, 10, 15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 using French connection
level of accuracy 1、0.5
Range degree 1:10、1:15、1:20
Instrument material 304 stainless steel, 316 (L) stainless steel, etc.
Measured medium temperature (℃) -20~+120℃
Environmental conditions Temperature -10 ~ + 55 ℃, relative humidity 5% ~ 90%, atmospheric pressure 86 ~ 106kPa
output signal Sensor: pulse frequency signal, low level ≤0.8V, high level ≥8V
Transmitter: Two-wire 4-20mA current signal
Power supply Sensor: + 12VDC, + 24VDC (optional)
Transmitter: + 24VDC
On-site display type: instrument comes with 3.2v lithium battery
Signal transmission line STVPV3 × 0.3 (three-wire system), 2 × 0.3 (two-wire system)
Transmission distance ≤1000m
Signal line interface Basic type: Hausmann connector. Explosion-proof type: female thread M20 × 1.5
Explosion-proof grade Basic type: non-explosion-proof products. Explosion-proof type: EsdllBT6
Protection class IP65
Instrument calibermmDN Normal flow rangem³/h Expand the flow rangem³/h Conventional tolerance pressureMPa Special pressure resistance gradeMPa)(Flange connection
4 0.04-0.25 0.04-0.4 6.3 121625
6 0.1-0.6 0.06-0.6 6.3 121625
10 0.2-1.2 0.15-1.5 6.3 121625
15 0.6-6 0.4-8 6.32.5Flange 4.06.3121625
20 0.8-8 0.45-9 6.32.5Flange 4.06.3121625
25 1-10 0.5-10 6.32.5Flange 4.06.3121625
32 1.5-15 0.8-15 6.32.5Flange 4.06.3121625
40 2-20 1-20 6.32.5Flange 4.06.3121625
50 4-40 2-40 2.5 4.06.3121625
65 7-70 4-70 2.5 4.06.3121625
80 10-100 5-100 2.5 4.06.3121625
100 20-200 10-200 2.5 4.06.3121625
125 25-250 13-250 1.6 2.54.06.3121625
150 30-300 15-300 1.6 2.54.06.3121625
200 80-800 40-800 1.6 2.54.06.3121625

Model

Description

Types of

C

 

 

 

 

 

Basic type:+ 24V power supply, three-wire pulse output

F

 

 

 

 

 

+ 24V4 ~ 20mA two-wire current output

Y

 

 

 

 

 

Intelligent: battery-powered on-site display, no signal output

B

 

 

 

 

 

Intelligent: + 24V power supply, on-site display with two-wire 4-20mA current output

B1

 

 

 

 

 

Intelligent: + 24V power supply, on-site display with RS485 communication protocol

B2

 

 

 

 

 

Intelligent: + 24V power supply, on-site display with HART communication protocol

Accuracy class

0.5

 

 

 

 

Accuracy class 0.5

10

 

 

 

 

Accuracy class 1.0

Turbine type

K

 

 

 

Wide measuring range

S

 

 

 

Standard measuring range

Texture

P

 

 

304 stainless steel

R

 

 

316 (L) stainless steel

Explosion proof

O

 

Non-explosion-proof type

E

 

Explosion-proof type (ExdBT66)

Pressure Level

S

Normal (reference flow range table)

H(x)

High pressure (reference flow range table)

1.filter                       2.Front straight section           3. impeller
4.Preamplifier          5.case                    6.Back straight pipe section
1.Compression ring          2.Bolt 4 × 14            3.washer   
4.Sealing washer             5.Wire1Cr18Ni9Ti-0.8×2.5       
6. Filter                             7.pedestal
 Schematic diagram of LWGY-4 ~ 10 sensor structure and installation dimensions
1.case        2.Front guide        3.impeller          4.Rear guide    5.Preamplifier 1.Jack joint          2.Front guide      3.Rising circle         4.case
5.Preamplifier      6.impeller           7.Bearing                8.axis
 Schematic diagram of LWGY-15 ~ 40 sensor structure and installation dimensions  Schematic diagram of LWGY-50 ~ 200 sensor structure and installation dimensions
Nominal diametermm L(mm) G Dmm dmm 孔数
4 225 G1/2"      
 6  225 G1/2"
10 345 G1/2"
15 75 G1" Ø65 Ø14 4
20 80 G1" Ø75 Ø14 4
25 100 G5/4" Ø85 Ø14 4
32 140 G2" Ø100 Ø14 4
40 140 G2" Ø110 Ø18 4
50 150 G5/2" Ø125 Ø18 4
65 170   Ø145 Ø18 4
80 200 Ø160 Ø18 8
100 220 Ø180 Ø18 8
125 250 Ø210 Ø25 8
150 300 Ø250 Ø25 8
200 360 Ø295 Ø23 12
 