Miniature Glass rotameter

It can detect the tiny flow of gas or liquid, and has a light structure, sensitive adjustment and simple installation.
INQUIRY
Description SELECTION CRITERIA INSTALLATION AND USE INSTALLATION AND USE
LZB- ( )W/WB series mini flow glass rotameters include DN3, DN4, DN6, DN10 which are featured with light structure,sensitive adjustment ,easy installation.They can carry out the micro gas and liquid measurement and analyses in the industries of environment protection, medical service, light industry, food industry, scientific research etc.They can be used together with analytical apparatus, environment protection instruments,medical facilities and other scientific experiment devices.

The flowmeter is mainly composed of a conical glass tube that expands from below and a float that moves up and down as the fluid flow rate changes (Figure 1). The sum of the lift force S generated by the fluid kinetic energy on the float and the buoyancy A of the fluid When the float's own gravity G, the float is in equilibrium and stable at a certain height position. The scale on the cone indicates the flow value of the fluid. The reading position of the float in the flow meter is shown in Figure 2.
figure 1 figure 2

 
Bore
DN
(mm)
Model Measuring range Accuracy
class
Taper pipe
length
(mm)
State of the liquid allowed
Water,20 Air 20101325Pa Temperature() Pressure(MPa)
3 LZB-3W
LZB-3WB
04-4ml/min
0.6-6ml/min
1-10ml/min
1.6-16ml/min
2.5-25ml/min
4-40ml/min
6-60ml/min
10-100ml/min
6-60ml/min
10-100ml/min
16-160ml/min
25-250ml/min
40-400ml/min
60-600ml/min
100-1000ml/min
160-1600ml/min
25:4 100 0-60 0.2
4 LZB-4W
LZB-4WB
16-160ml/min
25-250ml/min
40-400ml/min
0.3-3L/min
0.6-6L/min
0.7-7L/min
6 LZB-6W
LZB-6WB
0.04-0.4L/min
0.06-0.6L/min
0.1-1L/min
0.7~7L/min
1-10L/min
1.5-15L/min
2.5
10 LZB-10W
LZB-10WB
0.1-1L/min
0.16~1.6L/min
3-30L/min
5-45L/min
120
 
Bore(DN) Dimensions 
Model
A B C D E* M N Mounting holes on equipment Remark
Hose joint Metal pipe joint
3 LZB-3W
LZB-3WB
26 136 50 24 <50 116 Ф8 M10×1 2-ф11 Not including
special
shape
and coupling
dimension
4 LZB-4W
LZB-4WB
28 136 56 27.5 <52 116 Ф8 M10×1 2-ф11
6 LZB-6W
LZB-6WB
28 136 58 29.5 <55 116 Ф10 M12×1 2-ф11
10 LZB-10W
LZB-10WB
28 160 60 29.5 <55 140 Ф11 M16×15 2-ф11

1. The flowmeter should be installed vertically (the angle between the centerline of the flowmeter and the plumb line should not exceed 5 ° C). For newly installed pipelines, the pipeline should be flushed clean before installing the flowmeter. The measured fluid enters from the lower end of the flowmeter and exits from the upper end
2. The installation of the flow meter uses a nozzle as a pillar. Open 2 ~ 011 holes (with a thickness not exceeding 5 mm) on the device, with a hole distance of 116 or 140 mm. Pass two nozzles M10 × 1 through the mounting holes, and fasten the flowmeter with a flat hexagon nut
3. Do not mix large particles of dirt in the measured fluid, otherwise the float will jam or block the flowmeter path, affecting the normal operation of the flowmeter. Install a filter upstream of the meter as needed
4.The pressure of the measured fluid entering the flowmeter must be stable, otherwise it will cause the float to fluctuate and cannot be measured correctly.A buffer or a setter should be set upstream of the flowmeter.
5.When using a flow meter, the flow regulating valve should be slowly opened to prevent the float from striking upwards and damaging the glass cone.
6. If flowmeter leakage is found, tighten the inlet and outlet nozzles and the pressure nut of the flow control valve. If the above method does not work, the seal ring should be replaced if it fails.
7. Cones and floats are contaminated and should be cleaned in time. Regularly check the flowmeter for errors.Once the error is exceeded, the float or cone tube should be replaced or recalibrated.
8. When the measured fluid and state (pressure, temperature) is inconsistent with the scale and state on the flow meter, the displayed value must be corrected according to the measured fluid and state.
 



 