mini flow metal pipe float flowmeter

LZW/WB LZZ(D)Wis a flowmeter of metal pipe float type with characteristics of firmness¡¢stability and widely application. Selfacting
INQUIRY
Description SELECTION CRITERIA INSTALLATION AND USE INSTALLATION AND USE

LZWB/WLZZ(D)Wis a flowmeter of metal pipe float type with characteristics of firmness¡¢stability and widely application. Selfacting pressure controller(constant current valve) can be choosed as options.
LZW/LZWB connected horizontally .LZW isn't equipped with control valve while LZWB is equipped with control valve.
LZWH installed vertically and equipped without control valve,also cannot match with constant current valve as options



 

Measuring range:

Media temperature:-40℃~150℃

Water: 20℃6L/h-100L/h

Ambient temperature:-25℃~65℃

Air: 20℃101325Pa 50L/h-3400L/h

Connection size:1/4NPT internal thread or sleeve connectingΦ8(Φ6 etc.)pipe

Range ratio: 10:1 or 5:1

Material:Base:Stainless steel

Accuracy : 4% Fs

Housing of indicator:Cast aluminum

Maximum pressure: 2.5MPa(can be increased as required)

Cone floater:Stainless steel

Taper pipe number

Water(L/h)

Air(L/h)

Pressure loss(kPa)

W01

 

50

1.2

W02

 

100

1.4

W03

6

150

1.5

W04

10

400

1.8

W05

25

800

3.5

W06

40

1250

6.5

W07

60

2000

13.0

W08

80

2500

23.5

W09

100

3400

40.0

 
LZZW—F12 (Horizontal Connection)  
LZDW—F12 ( Horizontal Connection)  

Installation and maintenance
1. Before the flowmeter is installed in the process pipeline, the process pipeline should be purged or cleaned to prevent impurities in the pipeline from blocking the meter and affecting the normal operation.
2. The flowmeter should be installed vertically with the medium flowing upward. The angle between the centerline of the flowmeter and the plumb line should not exceed 5 °.
3. To prevent the pipeline from being deformed under pressure, the flowmeter interface must be centered and parallel to the pipeline axis. If necessary, properly support the pipeline on both sides of the flowmeter to prevent vibration and reduce the axial pressure of the flowmeter.
4. If the medium contains solid impurities, a filter should be installed upstream of the flow meter.
5. In order to facilitate maintenance and cleaning, it is recommended to install a bypass line.
6. To ensure the flow indication is stable, it is recommended to install a flow regulating valve downstream of the flow meter.
7. When measuring liquid, the working pressure should be not less than 2 times the maximum pressure loss; when measuring the gas, the working pressure should be not less than 5 times the maximum pressure loss to make the flowmeter work stably.
8. This instrument works based on the principle of magnetic coupling. It should be ensured that the magnetic field generated by other equipment around the instrument does not affect the measurement results.


 