Contact Us
5th Floor, Jingwei Building, 7 Yanzheng Middle Avenue, Wujin District, Changzhou City, Jiangsu Province, China
+86-519 86577655
flowmetercn.com
You are here: Home > process analytics

CH6 series single channel thermal watch

Thermometer refers generally to the instruments used for the measurement and control of common thermal quantities.The commonly used thermal quantities generally include temperature, humidity, pressure, level and composition.
INQUIRY
Description SELECTION CRITERIA INSTALLATION AND USE FIELD INSTALLATION

Thermometer refers generally to the instruments used for the measurement and control of common thermal quantities.The common thermal quantities generally include temperature, humidity, pressure, liquid level and composition.Single channel thermal meters include 6 series products.The main differences are Measurement accuracy, measurement and control speed, and optional functions
◆ CH6 is a general economic type, with 2 points alarm output and transmitter power supply as standard, and optional transmission output. Meets the requirements of 0.5 level display, alarm and transmission applications
◆The XST series is a standard type with a precision level of 0.2, which meets most application requirements. The sw series is a standard type. The difference from XST is that the input signal is universal input. It can be selected by setting.
◆ XSE and XSE6 series are high precision. XSE6 measurement and control speed can be set, taking into account the requirements of accuracy and speed
◆XSE thermal resistance adopts 4-wire system, and the cold junction compensation element of the thermocouple is external, so it can achieve higher system measurement accuracy
◆The XSF series is characterized by high speed, which can reach a maximum measurement speed of 300 times .
◆XSBT is a two-wire loop display, which does not require power supply and can be connected in a 4-20mA loop to achieve data display.
Model code
 
Technical Parameters
CH6- 0.5-level measurement accuracy: 5 measurement and control speeds per second
dimension AH 160 × 80 × 125mm horizontal opening size: 152 × 76
AS 80 × 160 × 125mm vertical opening size: 76 × 152
B 96 × 96 × 76mm hole size: 92 × 92
CH 96 × 48 × 82mm horizontal opening ruler: 92 × 45
CS 48 × 96 × 82mm vertical opening size: 45 × 92
D 72 × 72 × 75mm hole size: 68 × 68
E 48 × 48 × 108mm opening size: 45.5 × 45.5
Panel specifications 4-digit LED
input signal Universal input, select input signal through parameter setting
Thermocouple (K / S / R / B / N / E / J / T)
Thermal resistance t100 / Cu100 / CU50 / BA1 / BA2 / G53) Voltage (0 ~ 5) V / (1-5) V
Current (4-20) ma / (0-10) ma / (0-20) ma
Call the police 2 relay outputs, 250VAC / 3A, resistive load
Transmit (optional)
Resolution, 1/3000
Load capacity 600Ω
A1 Current output (4-20) mA. (0-20) mA. (0-10mA
Current output is isolated from external power supply (when external power supply is required)
A1G Current output is isolated from external power supply (when external power supply is required) External power supply B124V + 5% Below 50mA 100-240VAC50 / 60Hz
External power supply B1 24V+5%50mA以下
 
Power Specifications
V0 100-240V AC 50/60Hz
V1 10-24V AC 50/60 Hz;10-24V DC(CH CS only)
AH size 160 × 80 size instrument B size 96 × 96 size instrument
CH size 96 ×48 size instrument D size 72 × 72 size instrument
 
E size 48 × 48 size instrument  

Maybe you like

Review